aqq_闺蜜放荡交换h_人人舔人人插_韩国三级hd中文字幕久久精品

產(chǎn)品banner

您當(dāng)前的位置 : 首 頁(yè) > 產(chǎn)品中心 > 日本YUKEN油研

產(chǎn)品中心 Product

聯(lián)系我們Contact Us

上海乾拓貿(mào)易有限公司

電 話:021-39526589

網(wǎng)址:5xf8s3.cn

地 址:上海嘉定區(qū)嘉涌路99弄6號(hào)樓713室

日本油研卸荷溢流閥主要,MSW-01-X-30?

日本油研卸荷溢流閥主要,MSW-01-X-30?

  • 所屬分類:日本YUKEN油研
  • 瀏覽次數(shù):
  • 發(fā)布日期:2017-11-24
  • 產(chǎn)品概述
  • 性能特點(diǎn)
  • 技術(shù)參數(shù)

日本油研卸荷溢流閥主要,MSW-01-X-30    

上海乾拓貿(mào)易有限公司

聯(lián)系人:楊江玲

企業(yè)QQ:2880626083

手 機(jī):18917074297(微信)

電 話:021-39529830-8012

郵箱;18917074297@163.com

地址:上海市嘉定區(qū)江橋嘉涌路6號(hào)樓713室 

 Limit the pressure drop between the valve and the accumulator in an accumulator circuit

 below 10% of the cut-out pressure.

Limit the drain port back pressure below 2% of the cut-out pressure.  

Recommended Viscosity and Oil Temperatures  2  Viscosity ranging between 15 - 400 mm /s (77 - 1800 SSU)

when the system pressure reaches to a cut out pressure (adjusted maximum),

 the valve acts to divert the pump delivery to the reservoir a t low pressure, 

the hydraulic fluids which may otherwise lead to breakdowns and shorten 

the life of the valves.  Please maintain the degree of contamination within NAS 1638-Grade 

12.  Use 25 μm or finer line filter.  Control of Contamination

To adjust the pressure, loosen the lock nut and turn the pressure adjustment

 handle slowly clockwise for higher p ressures or anti-clockwise for lower pressures. 

 After adjustments, do not forget to tighten the lock nut. 

Oil temperatures between -15/+70°C (5 - 158°F).  Use hydraulic fluids which satisfy 

the recommended viscosity and oil temperatures given above

pump with the same manner as described above during load operation of the small volume pump.

Fluid Types Hydraulic Fluids Any type of hydraulic fluids listed in the table below can be used.

Note: For use with hydraulic fluids other than those listed above, 

otherwise not only will the valve fail to operate p roperly 

but also the line pressure will rise infinitely.  Extend the end of the drain pipe into fluid.

These valves are used to operate the pumps with minimum load in accumulator circuits

or in high-low pump circuits.  In accumulator circuits, 

thus the pump is unloaded automatically.  When the accumulator pressure drops to the cut in pressure 

(refer to characteristic chart on page 5), the valve directs the pump delivery to the accumulator 

and hydraulic system.  An integral check valve prevents reverse flow through the valve from the accumulator. 

 In high-low pump circuits, the valve acts to unload the large volume 

Instructions Take care not to neglect connecting the drain pipe to the tank;

please consult your Yuken representatives in advance. Recommended Viscosity and Oil Temperatures

Due caution must be paid to maintaining control over contamination of

日本油研卸荷溢流閥主要,MSW-01-X-30    

標(biāo)簽

近期瀏覽:

在線客服